An Assessment of a Long-Throated Flume with a Broad-Crested Weir Cross-Section for Flow Measurement

Document Type : Research Paper

Authors

Abstract

Water-use-efficiency, which is a matter of utmost importance in irrigated-agriculture in the water-short Iran, requires installation of accurate flow measurement devices on the outlets of delivery channels. Accuracy, low cost, and ease of installation and measurement are the criteria for a good measuring device.  As a long-throated flume with a broad-crested weir cross-section had been studied in detail by Zand-Parsa, and the Win Flume software was available for the design of the flume and processing of the collected data, 10 such flumes were installed in 3, third degree channels in the Dorudzan Irrigation District in 2007; however, this study was implemented in the 2012 irrigation season, using 3-5 replication for each flume set up. Both our collected data and the Win Flume program validated the equation developed by Zand -Parsa. It was observed that the percentage error in measuring low flows ranged 12-21, which was much higher than that of the maximum flow? Based on these results, the large scale use of this device and the application of the Zand-Parsa equation are recommended

Keywords


2- Ackers, P., W. R. White, J. A. Perkins,
and A. J. M. Harrison, 1978, Weirs and
Flumes for Flow Measurement, John
Wiley & Sons, New York,.
3- Bos, M. G., J. A. Replogle, and A. J.
Clemmens, 1991, Flow Measuring Flum-
es for Open Channel Systems, American
Society of Agricultural Engineers, St.
Joseph, MI, (republication of 1984
edition by John Wiley & Sons).
4- Bos, M.G. and Y. Reinink. 1981. Head
loss over long-throated flumes. J. Irrigation. ASCE.107:87-102.
5- Clements, A.J., T.L. Wahl, M.G. Bos,
and J.A. Replogle. 2001, Water measureement with flumes and weirs. ILRI,
Wagenigen The Netherlands. 382p.
6- Replogle, J.A. 1975, Critical flow flumes
with complex cross-section. In: Irrigation
and Drainage in Age of Competition for
Resources, Specialty Conference Proceding, ASCE, Logon, Utah, pp. 366-388.
7- Replogle, J.A. 1999, Flow measurement.
Journal of Irrigation and Drainage Systems. 12: 71-83.
8- Replogle, J.A., Clements A.J., Pugh,
C.A. 2004, Hydraulic Design Handbook,
chapter 21, USDA -ARS Water conservation Laboratory, Phoenix, Arizona
9- U.S. Bureau of Reclamation, 1997, Water
Measurement Manual, 3rd ed., U.S.
Government Printing Office, Washington, DC 20402
10- Wahl, Tony L., Albert J. Clemmens, John
A. Replogle, and Marinus G. Bos,2000,
"WinFlume - Windows-Based Software
for the Design of Long-Throated Measuring Flumes". Fourth Decennial National IrrigationSymposium, American
Society of Agricultural Engineers, Nov.
14-16, Phoenix, Arizona.
11- Zand-Parsa, Sh. 2008, Difficulties of
Irrigation water measurements in Iran
and recommendation for a suitable
method. Water Management in Iran and
the United States, pp121-131